[The reason and treatment method of water leakage in the chiller!]
Release date:[2022/5/7] Is reading[254]次

The condition for the normal operation of the water machine is that the water circulation, refrigerant circulation, and electric control system must be kept normal. If there is a problem on the one hand, the operation of the chiller will be abnormal, which will affect production. At the connection of the water pipe, advance treatment is conducive to the normal operation of the chiller.

Let's take a look at the causes and water-cooled screw chillers of water leakage from the chiller according to the environment, and advocate collection for backup. The water circulation system of the chiller is composed of the water inlet pipe, the evaporator, the water outlet pipe, the water tank, the chilled water pump, the cooling water pump, the condenser, and the pipes and valves at the joints. Approach.

Water-cooled screw chiller at the inlet and outlet of the chiller is usually caused by loose or cracked bolts at the joint, which can be corrected or replaced; water leakage from the evaporator shell of the chiller should be checked to see if there is water seepage at the weld of the evaporator shell. Welding correction should be carried out if necessary; there is water leakage at the float valve of the chiller, and the float valve controls the switch of the water inlet valve according to the buoyancy. The treatment method is to check and adjust the position of the ball valve. If it is damaged, it should be replaced and repaired.

Water leakage occurs in the perforation of the condenser inside the chiller. The water-cooled screw chiller is to find the fault point and correct it; the water tank of the chiller is too full to cause the cooling water to fluctuate and leak during operation. The water-cooled screw chiller is to lower the water level in the water tank; Because the welding position of the water tank is corroded and leaked, it needs to be re-welded for repair.